All SPEC SFS97_R1 ResultsThese results have been submitted to SPEC, see the disclaimer before studying any results. |
NFS version 3 || NFS version 2
Last publication update: Wed Jun 18 11:48:06 2008
Company | System | CPU # | Proto | Result | ORT1 | Disclosure |
---|---|---|---|---|---|---|
BlueArc Corporation | BlueArc Titan 2100 | 1 core, 1 chip, 1 core/chip + 7 FPGAs | TCP | 76060 | 2.25 | HTML Text PS |
BlueArc Corporation | BlueArc Titan 2200 | 1 core, 1 chip, 1 core/chip + 7 FPGAs | TCP | 98131 | 2.34 | HTML Text PS |
BlueArc Corporation | BlueArc Titan 2200, 2-Node Active/Active Cluster | 2 cores, 2 chips, 1 core/chip (with 14 FPGAs, 7 per node) | TCP | 195502 | 2.37 | HTML Text PS |
BlueArc Corporation | Titan 2200, 2 node active/active cluster | 2 core, 2 chip, 1 core/chip + 14 FPGAs | TCP | 192915 | 1.72 | HTML Text PS |
BlueArc Corporation | Titan 3110-F | 1 core, 1 chip, 1 core/chip + 12 FPGAs | TCP | 96428 | 2.11 | HTML Text PS |
BlueArc Corporation | Titan 3110-F Cluster | 2 cores, 2 chips, 1 core/chip + 24 FPGAs | TCP | 192805 | 1.91 | HTML Text PS |
BlueArc Corporation | Titan 3200 | 1 core, 1 chip, 1 core/chip + 13 FPGAs | TCP | 194909 | 2.43 | HTML Text PS |
BlueArc Corporation | Titan 3210 | 1 core, 1 chip, 1 core/chip + 13 FPGAs | TCP | 180243 | 2.34 | HTML Text PS |
BlueArc Corporation | Titan 3210 Cluster | 2 cores, 2 chips, 1 core/chip + 26 FPGAs | TCP | 359416 | 2.16 | HTML Text PS |
BlueArc Inc. | Titan 32 | 1 core, 1 chip, 1 core/chip (with 7 FPGAs) | TCP | 50858 | 1.76 | HTML Text PS |
BlueArc Inc. | Titan 32 | 2 cores, 2 chips, 1 core/chip (1 core, 1 chip per node with 14 FPGAs) | TCP | 101571 | 1.78 | HTML Text PS |
Compaq Computer Corporation | Compaq AlphaServer ES45 1000 | 4 | UDP | 27566 | 1.40 | HTML Text PS |
DataChorus Co. Ltd | ClusStor SG C7000 (Failover Cluster) | 4 cores, 4 chips, 1 core/chip (2 cores per node) | UDP | 30024 | 1.80 | HTML Text PS |
EMC Corp | Celerra NS40G Cluster 2 X-Blades | 4 cores, 4 chips, 1 core/chip with HT Technology enabled (2 chips per blade) | TCP | 76068 | 1.83 | HTML Text PS |
EMC Corp | Celerra NS80G Failover Cluster 2 Xblade60's (1 stdby) | 2 cores, 2 chips, 1 core/chip with HT Technology enabled (2 chips per Xblade60) | TCP | 43318 | 1.52 | HTML Text PS |
EMC Corp | Celerra NS80G Failover Cluster 3 Xblade60's (1 stdby) | 4 cores, 4 chips, 1 core/chip with HT Technology enabled (2 chips per Xblade60) | TCP | 86372 | 1.49 | HTML Text PS |
EMC Corp | Celerra NS80G Failover Cluster 4 Xblade60's (1 stdby) | 6 cores, 6 chips, 1 core/chip with HT Technology enabled (2 chips per Xblade60) | TCP | 123109 | 1.79 | HTML Text PS |
EMC Corp. | Celerra 510 cluster (1FS, non-failover) | 2 | TCP | 16772 | 2.43 | HTML Text PS |
EMC Corp. | Celerra 510 cluster (2FS, non-failover) | 4 | TCP | 33128 | 2.51 | HTML Text PS |
EMC Corp. | Celerra 514x1+1 Failover Cluster / Symmetrix DMX1000-P | 2 | TCP | 26156 | 1.59 | HTML Text PS |
EMC Corp. | Celerra 514x4+1 Failover Cluster / Symmetrix DMX1000-P | 8 (2 per node) | TCP | 100940 | 1.86 | HTML Text PS |
EMC Corp. | Celerra NS40 Failover Cluster 2 X-Blades (1 stdby) | 2 cores, 2 chips, 1 core/chip with HT Technology enabled (2 chips per X-blade) | TCP | 37382 | 2.45 | HTML Text PS |
EMC Corp. | Celerra NS500 Failover Cluster (one secondary) | 2 cores, 2 chips, 1 core/chip with HT Technology enabled | TCP | 25891 | 2.14 | HTML Text PS |
EMC Corp. | Celerra NS600 Cluster (2FS, primary/primary, 8GB BE) | 4 [2 per datamover] | TCP | 45045 | 2.67 | HTML Text PS |
EMC Corp. | Celerra NS600 Failover Cluster (1FS, primary/secondary, 8GB BE) | 2 | TCP | 25656 | 2.05 | HTML Text PS |
EMC Corp. | Celerra NS600 cluster (2FS, primary/primary, 4GB BE) | 4 [2 per datamover] | TCP | 38459 | 3.94 | HTML Text PS |
EMC Corp. | Celerra NS700 Failover Cluster (one secondary) | 2 | TCP | 36335 | 2.23 | HTML Text PS |
EMC Corp. | Celerra NS700G Cluster / CLARiiON CX700x2 | 4 (2 per Data Mover) | TCP | 71482 | 2.54 | HTML Text PS |
EMC Corp. | Celerra NS704G Failover Cluster / CLARiiON CX700x2 | 6 cores, 6 chips, 1 core/chip with HT Technology enabled (2 chips per Data Mover) | TCP | 100150 | 2.63 | HTML Text PS |
EMC Corp. | Celerra NSX Cluster 4 X-Blade 60 (1 stdby) DMX | 6 cores, 6 chips, 1 core/chip with HT Technology enabled (2 chips per blade) | TCP | 137310 | 1.48 | HTML Text PS |
EMC Corp. | Celerra NSX Cluster 8 X-Blade 60 (1 stdby) 2 DMX | 14 cores, 14 chips, 1 core/chip with HT Technology enabled (2 chips per blade) | TCP | 320064 | 1.64 | HTML Text PS |
EMC Corp. | Celerra/CX600 | 2 | TCP | 16014 | 2.55 | HTML Text PS |
EMC Corp. | Celerra/CX600 | 4 (2 per node, 2 nodes) | TCP | 30549 | 3.13 | HTML Text PS |
EMC Corp. | EMC Celerra NS20 Multi-protocol Storage | 2 cores, 2 chips, 1 core/chip with HT Technology enabled (2 chips per blade) | TCP | 22248 | 2.17 | HTML Text PS |
Exacube Systems Inc. | Netbine500 | 4 cores, 4 chips, 1 core/chip (2 cores per node) | UDP | 15014 | 1.30 | HTML Text PS |
Exanet Inc. | ExaStore EX200FC | 4 cores, 4 chips, 1 core/chip (2 cores per node) | TCP | 61070 | 1.18 | HTML Text PS |
Exanet Inc. | ExaStore EX200FC | 4 cores, 4 chips, 1 core/chip (2 cores per node) | UDP | 71185 | 1.21 | HTML Text PS |
Exanet Inc. | ExaStore EX200FC (High Performance Cluster) | 8 cores, 8 chips, 1 core/chip (4 cores per node) | TCP | 119763 | 1.17 | HTML Text PS |
Exanet Inc. | ExaStore EX200FC (High Performance Cluster) | 8 cores, 8 chips, 1 core/chip (4 cores per node) | UDP | 143880 | 1.47 | HTML Text PS |
Exanet Inc. | ExaStore EX400FC | 8 cores, 8 chips, 1 core/chip (2 cores per node) | TCP | 121738 | 1.07 | HTML Text PS |
Exanet Inc. | ExaStore EX400FC | 8 cores, 8 chips, 1 core/chip (2 cores per node) | UDP | 139061 | 1.13 | HTML Text PS |
Exanet Inc. | ExaStore EX600FC | 12 cores, 12 chips, 1 core/chip | TCP | 178156 | 1.04 | HTML Text PS |
Exanet Inc. | ExaStore EX600FC | 12 cores, 12 chips, 1 core/chip | UDP | 203182 | 1.08 | HTML Text PS |
GlueSys Co, Ltd. | AnyStor GW-C (failover Cluster) | 8 cores, 4 chips, 2 cores/chip (2 chips per node) | TCP | 66932 | 0.64 | HTML Text PS |
Hewlett Packard | HP AlphaServer ES45 1250 | 4 | UDP | 32772 | 1.72 | HTML Text PS |
Hewlett Packard | HP AlphaServer GS1280 Model 4 7/1150 | 4 | UDP | 40579 | 1.39 | HTML Text PS |
Hewlett Packard | HP AlphaServer GS1280 Model 8 7/1150 | 8 | UDP | 66235 | 1.78 | HTML Text PS |
Hewlett Packard | HP Surestore NAS-105L | 4 | TCP | 12371 | 3.83 | HTML Text PS |
Hewlett Packard | HP Surestore NAS-105L | 4 | UDP | 12970 | 4.06 | HTML Text PS |
Hewlett Packard | HP Surestore NAS-105LC Failover Cluster | 8 (4 processors/node) | UDP | 20689 | 4.12 | HTML Text PS |
Hewlett Packard | HP Surestore NAS-105LC Failover Cluster | 8 (4 processors/node) | TCP | 21343 | 4.26 | HTML Text PS |
Hewlett Packard | HP server rp5470 | 4 | TCP | 16003 | 2.04 | HTML Text PS |
Hewlett Packard | HP server rp5470 | 4 | UDP | 17979 | 2.11 | HTML Text PS |
Hewlett Packard | rp2470 | 2 | TCP | 10427 | 1.94 | HTML Text PS |
Hewlett Packard | rp2470 | 2 | UDP | 12091 | 1.89 | HTML Text PS |
Hewlett Packard | rp7410 | 8 | TCP | 29571 | 3.92 | HTML Text PS |
Hewlett Packard | rp7410 | 8 | UDP | 39261 | 3.92 | HTML Text PS |
Hewlett-Packard | HP ProLiant DL585 G2 Storage Server | 8 cores, 4 chips, 2 cores/chip | TCP | 35164 | 1.88 | HTML Text PS |
Hewlett-Packard | HP ProLiant DL585 G2 Storage Server | 8 cores, 4 chips, 2 cores/chip | UDP | 38209 | 1.27 | HTML Text PS |
Hewlett-Packard | HP Server rx5670 | 4 | TCP | 22536 | 2.20 | HTML Text PS |
Hewlett-Packard | HP Server rx5670 | 4 | UDP | 28740 | 2.18 | HTML Text PS |
Hewlett-Packard | HP server rp7400 | 4 | TCP | 14104 | 2.13 | HTML Text PS |
Hewlett-Packard | HP server rp7400 | 4 | UDP | 15202 | 2.29 | HTML Text PS |
Hewlett-Packard | hp ProLiant DL380 G4 Storage Server SAN Storage Model | 2 cores, 2 chips, 1 core/chip (Hyper-Threading Technology enabled) | TCP | 9710 | 2.29 | HTML Text PS |
Hewlett-Packard | hp ProLiant DL380 G4 Storage Server SAN Storage Model | 2 cores, 2 chips, 1 core/chip (Hyper-Threading Technology enabled) | UDP | 11394 | 1.66 | HTML Text PS |
Hewlett-Packard | hp ProLiant DL580G2 Storage Server | 4 cores, 4 chips, 1 core/chip | TCP | 9209 | 2.38 | HTML Text PS |
Hewlett-Packard | hp ProLiant DL580G2 Storage Server | 4 cores, 4 chips, 1 core/chip | UDP | 11082 | 1.78 | HTML Text PS |
Hewlett-Packard | hp ProLiant DL585 Storage Server | 4 cores, 2 chips, 2 cores/chip | TCP | 22416 | 1.74 | HTML Text PS |
Hewlett-Packard | hp ProLiant DL585 Storage Server | 4 cores, 2 chips, 2 cores/chip | UDP | 23064 | 1.87 | HTML Text PS |
Hewlett-Packard | hp StorageWorks NAS 8000 | 4 | UDP | 11704 | 3.32 | HTML Text PS |
Hewlett-Packard | hp StorageWorks NAS 8000 Failover Cluster | 8 (4 per node) | UDP | 20167 | 3.48 | HTML Text PS |
Hewlett-Packard | hp server rx4610 | 4 | TCP | 14848 | 2.22 | HTML Text PS |
Hewlett-Packard | hp server rx4610 | 4 | UDP | 16791 | 2.07 | HTML Text PS |
Hitachi Data Systems | Hitachi High performance NAS Platform 2200, 2 node active/active cluster | 2 core, 2 chip, 1 core/chip + 14 FPGAs | TCP | 192915 | 1.72 | HTML Text PS |
Hitachi Data Systems | Lightning NAS Blade - 1 Cluster | 2 cores, 2 chips, 1 core/chip (1 per NAS Blade) | UDP | 36101 | 2.11 | HTML Text PS |
Hitachi Data Systems | Lightning NAS Blade - 2 Cluster | 4 cores, 4 chips, 1 core/chip (1 per NAS Blade) | UDP | 72650 | 2.16 | HTML Text PS |
Hitachi Data Systems | Lightning NAS Blade - 3 Cluster | 6 cores, 6 chips, 1 core/chip (1 per NAS Blade) | UDP | 108369 | 2.13 | HTML Text PS |
Hitachi Data Systems | Lightning NAS Blade - 4 Cluster | 8 cores, 8 chips, 1 core/chip (1 per NAS Blade) | UDP | 144941 | 2.22 | HTML Text PS |
Hitachi Data Systems | NetApp GF940 / HDS 9980V (32GB cache) | 1 core, 1 chip, 1 core/chip | TCP | 19120 | 0.72 | HTML Text PS |
Hitachi Data Systems | NetApp GF940c Failover Cluster / HDS 9980V (32GB cache) | 2 cores, 2 chips, 1 core/chip (1 per node) | TCP | 36698 | 0.99 | HTML Text PS |
Hitachi Data Systems | NetApp GF960 / HDS 9980V (32GB cache) | 2 cores, 2 chips, 1 core/chip | TCP | 27023 | 0.82 | HTML Text PS |
Hitachi Data Systems | NetApp GF960c Failover Cluster / HDS 9980V (32GB cache) | 4 cores, 4 chips, 1 core/chip (2 per node) | TCP | 50139 | 1.04 | HTML Text PS |
IBM Corporation | IBM System p5 550Q (1500 MHz, 8 CPU, TCP) | 8 cores, 4 chips, 2 cores/chip (SMT enabled) | TCP | 118391 | 1.47 | HTML Text PS |
IBM Corporation | IBM System p5 570 (2.2GHz, 8 CPU, TCP) | 8 cores, 4 chips, 2 cores/chip (SMT enabled) | TCP | 169786 | 1.67 | HTML Text PS |
IBM Corporation | IBM TotalStorage NAS Gateway 500 (UDP - Failover Cluster) | 8 (4 per node) | UDP | 68444 | 1.75 | HTML Text PS |
IBM Corporation | IBM eServer OpenPower 720 (1.65GHz, 4 CPU, TCP, Linux) | 4 cores, 2 chips, 2 cores/chip (SMT on) | TCP | 67347 | 0.79 | HTML Text PS |
IBM Corporation | IBM eServer OpenPower 720 (1.65GHz, 4 CPU, TCP, Linux) | 4 cores, 2 chips, 2 cores/chip (SMT on) | TCP | 73092 | 1.34 | HTML Text PS |
IBM Corporation | IBM eServer p5 510 (1650 MHz, TCP) | 2 cores, 1 chip, 2 cores/chip (SMT enabled) | TCP | 42033 | 1.28 | HTML Text PS |
IBM Corporation | IBM eServer p5 550 (1.65GHz, TCP) | 4 cores, 2 chips, 2 cores/chip (SMT enabled) | TCP | 75839 | 1.11 | HTML Text PS |
IBM Corporation | IBM eServer p5 570 (1.9GHz, 2 CPU, TCP, Linux) | 2 cores, 1 chip, 2 cores/chip (SMT on) | TCP | 45586 | 0.81 | HTML Text PS |
IBM Corporation | IBM eServer p5 570 (1.9GHz, 4 CPU, TCP, Linux) | 4 cores, 2 chips, 2 cores/chip (SMT on) | TCP | 81889 | 1.19 | HTML Text PS |
IBM Corporation | IBM eServer p5 570 (1.9GHz, TCP) | 8 cores, 4 chips, 2 cores/chip (SMT enabled) | TCP | 145362 | 1.17 | HTML Text PS |
IBM Corporation | IBM eServer pSeries 620 Model 6F0 | 4 | UDP | 19843 | 1.63 | HTML Text PS |
IBM Corporation | IBM eServer pSeries 620 Model 6F1 | 4 | UDP | 19843 | 1.63 | HTML Text PS |
IBM Corporation | IBM eServer pSeries 630 Model 6C4 (TCP) | 4 | TCP | 33569 | 1.48 | HTML Text PS |
IBM Corporation | IBM eServer pSeries 630 Model 6C4 (UDP) | 4 | UDP | 33593 | 1.46 | HTML Text PS |
IBM Corporation | IBM eServer pSeries 630 Model 6E4 (TCP) | 4 | TCP | 33569 | 1.48 | HTML Text PS |
IBM Corporation | IBM eServer pSeries 630 Model 6E4 (UDP) | 4 | UDP | 33593 | 1.46 | HTML Text PS |
IBM Corporation | IBM eServer pSeries 650 Model 6M2 (TCP) | 8 | TCP | 55526 | 1.43 | HTML Text PS |
IBM Corporation | IBM eServer pSeries 650 Model 6M2 (UDP) | 8 | UDP | 55825 | 1.42 | HTML Text PS |
IBM Corporation | IBM eServer pSeries 655 (UDP) | 4 | UDP | 42706 | 1.17 | HTML Text PS |
IBM Corporation | IBM eServer pSeries 660 Model 6M1 | 8 | UDP | 29962 | 1.63 | HTML Text PS |
IBM Corporation | IBM eServer pSeries 690 (1.7GHz, TCP) | 16 | TCP | 136200 | 1.02 | HTML Text PS |
IBM Corporation | IBM eServer pSeries 690 Turbo | 16 | UDP | 61120 | 1.40 | HTML Text PS |
Maxxan Systems Inc. | SG100 Failover Cluster | 4 (2 per node) | UDP | 22845 | 3.97 | HTML Text PS |
Maxxan Systems Inc. | SG100 Storage Gateway | 2 | UDP | 12083 | 1.88 | HTML Text PS |
Montilio Inc. | HP ProLiant DL380 G4 with RapidFile FCX2400 | 2 cores, 2 chips, 1 core/chip (Hyper-Threading Technology enabled) +1 FPGA onboard RapidFile HBA | TCP | 47586 | 1.34 | HTML Text PS |
Montilio Inc. | Penguin Computing Relion 2600 with RapidFile FCX2400 | 4 cores, 2 chips, 2 cores/chip | TCP | 70318 | 1.39 | HTML Text PS |
NEC Corporation | NV5300, 2 node active/active cluster | 4 cores, 4 chips, 1 core/chip (2 cores per node) | TCP | 14342 | 2.06 | HTML Text PS |
NEC Corporation | NV7200 Failover Cluster | 4 cores, 4 chips, 1 core/chip | TCP | 30452 | 1.64 | HTML Text PS |
NEC Corporation | NV7200S | 2 cores, 2 chips, 1 core/chip | TCP | 15249 | 1.63 | HTML Text PS |
NEC Corporation | NV7300, 2 node active/active cluster | 4 cores, 4 chips, 1 core/chip (2 cores per node) | TCP | 49117 | 1.66 | HTML Text PS |
NEC Corporation | NV7400, 2 node active/active cluster | 8 cores, 4 chips, 2 cores/chip (4 cores per node) | TCP | 62188 | 1.35 | HTML Text PS |
NEC Corporation | NV8210 | 2 | TCP | 25382 | 1.15 | HTML Text PS |
NSPLab(SM) Performed Benchmarking | SPECsfs2008 Reference Platform (SPECsfs97_R1 baseline) | 2 cores, 2 chips, 1 core/chip with HT Technology enabled | TCP | 3459 | 2.35 | HTML Text PS |
NetApp, Inc. | FAS3170 | 8 cores, 4 chips, 2 cores/chip | TCP | 137306 | 0.94 | HTML Text PS |
NetApp, Inc. | FAS6080A | 16 cores, 8 chips, 2 cores/chip | TCP | 164408 | 1.04 | HTML Text PS |
Network Appliance, Inc. | Data ONTAP GX System (24-node FAS6070) | 96 cores, 96 chips, 1 core/chip | TCP | 1032461 | 1.53 | HTML Text PS |
Network Appliance, Inc. | F810 (TCP, 18x36GB FCAL, GbE) | 1 core, 1 chip, 1 core/chip | TCP | 4974 | 1.64 | HTML Text PS |
Network Appliance, Inc. | F810 (UDP, 18x36GB FCAL, GbE) | 1 core, 1 chip, 1 core/chip | UDP | 4967 | 1.67 | HTML Text PS |
Network Appliance, Inc. | F810c Failover Cluster (TCP, 42x36GB FCAL, 2xGbE) | 2 cores, 2 chips, 1 core/chip (1 per node) | TCP | 9786 | 1.90 | HTML Text PS |
Network Appliance, Inc. | F810c Failover Cluster (UDP, 42x36GB FCAL, 2xGbE) | 2 cores, 2 chips, 1 core/chip (1 per node) | UDP | 9789 | 1.86 | HTML Text PS |
Network Appliance, Inc. | F820 (TCP, 26x36GB FCAL, GbE) | 1 core, 1 chip, 1 core/chip | TCP | 8020 | 1.78 | HTML Text PS |
Network Appliance, Inc. | F820 (UDP, 26x36GB FCAL, GbE) | 1 core, 1 chip, 1 core/chip | UDP | 8350 | 1.83 | HTML Text PS |
Network Appliance, Inc. | F820c Failover Cluster (TCP, 52x36GB FCAL, 2xGbE) | 2 cores, 2 chips, 1 core/chip (1 per node) | TCP | 13777 | 1.55 | HTML Text PS |
Network Appliance, Inc. | F820c Failover Cluster (UDP, 52x36GB FCAL, 2xGbE) | 2 cores, 2 chips, 1 core/chip (1 per node) | UDP | 14683 | 1.63 | HTML Text PS |
Network Appliance, Inc. | F825 | 1 core, 1 chip, 1 core/chip | TCP | 8062 | 1.18 | HTML Text PS |
Network Appliance, Inc. | F825c Failover Cluster | 2 cores, 2 chips, 1 core/chip (1 per node) | TCP | 13822 | 1.41 | HTML Text PS |
Network Appliance, Inc. | F840 (TCP, 42x36GB FCAL, GbE) | 1 core, 1 chip, 1 core/chip | TCP | 10909 | 1.45 | HTML Text PS |
Network Appliance, Inc. | F840 (UDP, 42x36GB FCAL, GbE) | 1 core, 1 chip, 1 core/chip | UDP | 11873 | 1.45 | HTML Text PS |
Network Appliance, Inc. | F840c Failover Cluster (TCP, 84x36GB FCAL, 2xGbE) | 2 cores, 2 chips, 1 core/chip (1 per node) | TCP | 19007 | 1.42 | HTML Text PS |
Network Appliance, Inc. | F840c Failover Cluster (UDP, 84x36GB FCAL, 2xGbE) | 2 cores, 2 chips, 1 core/chip (1 per node) | UDP | 20520 | 1.52 | HTML Text PS |
Network Appliance, Inc. | F880 (TCP, 50x36GB FCAL, GbE) | 2 cores, 2 chips, 1 core/chip | TCP | 16685 | 1.66 | HTML Text PS |
Network Appliance, Inc. | F880 (UDP, 50x36GB FCAL, GbE) | 2 cores, 2 chips, 1 core/chip | UDP | 17531 | 1.72 | HTML Text PS |
Network Appliance, Inc. | F880c Failover Cluster (TCP, 100x36GB FCAL, 2xGbE) | 4 cores, 4 chips, 1 core/chip (2 per node) | TCP | 28596 | 1.89 | HTML Text PS |
Network Appliance, Inc. | F880c Failover Cluster (UDP, 100x36GB FCAL, 2xGbE) | 4 cores, 4 chips, 1 core/chip (2 per node) | UDP | 30135 | 1.87 | HTML Text PS |
Network Appliance, Inc. | FAS2050 | 2 cores, 2 chips, 1 core/chip | TCP | 20027 | 1.37 | HTML Text PS |
Network Appliance, Inc. | FAS270c Failover Cluster | 4 cores, 2 chips, 2 cores/chip | TCP | 13620 | 1.98 | HTML Text PS |
Network Appliance, Inc. | FAS3020c | 2 cores, 2 chips, 1 core/chip (HT enabled) | TCP | 34089 | 1.77 | HTML Text PS |
Network Appliance, Inc. | FAS3040A | 4 cores, 4 chips, 1 core/chip | TCP | 60038 | 1.17 | HTML Text PS |
Network Appliance, Inc. | FAS3050c | 4 cores, 4 chips, 1 core/chip (HT enabled) | TCP | 47927 | 1.64 | HTML Text PS |
Network Appliance, Inc. | FAS3070A | 8 cores, 4 chips, 2 cores/chip | TCP | 85615 | 1.16 | HTML Text PS |
Network Appliance, Inc. | FAS6030A | 4 cores, 4 chips, 1 core/chip | TCP | 100295 | 0.92 | HTML Text PS |
Network Appliance, Inc. | FAS6070A | 8 cores, 8 chips, 1 core/chip | TCP | 136048 | 1.09 | HTML Text PS |
Network Appliance, Inc. | FAS920 | 1 core, 1 chip, 1 core/chip | TCP | 13460 | 0.98 | HTML Text PS |
Network Appliance, Inc. | FAS920c Failover Cluster | 2 cores, 2 chips, 1 core/chip | TCP | 26619 | 0.98 | HTML Text PS |
Network Appliance, Inc. | FAS940 | 1 core, 1 chip, 1 core/chip | TCP | 17419 | 0.99 | HTML Text PS |
Network Appliance, Inc. | FAS940c Failover Cluster | 2 cores, 2 chips, 1 core/chip (1 per node) | TCP | 33340 | 1.03 | HTML Text PS |
Network Appliance, Inc. | FAS960 | 2 cores, 2 chips, 1 core/chip | TCP | 25135 | 0.99 | HTML Text PS |
Network Appliance, Inc. | FAS960c Failover Cluster | 4 cores, 4 chips, 1 core/chip (2 per node) | TCP | 48143 | 1.13 | HTML Text PS |
Network Appliance, Inc. | FAS980 | 2 cores, 2 chips, 1 core/chip (HT Technology enabled) | TCP | 36063 | 0.95 | HTML Text PS |
Network Appliance, Inc. | FAS980c Failover Cluster | 4 cores, 4 chips, 1 core/chip (2 per node) (HT Technology enabled) | TCP | 68139 | 0.98 | HTML Text PS |
Network Appliance, Inc. | GF940/HDS 9980V (32GB cache) | 1 core, 1 chip, 1 core/chip | TCP | 19120 | 0.72 | HTML Text PS |
Network Appliance, Inc. | GF940c Failover Cluster/HDS 9980V (32GB cache) | 2 cores, 2 chips, 1 core/chip (1 per node) | TCP | 36698 | 0.99 | HTML Text PS |
Network Appliance, Inc. | GF960/HDS 9980V (32GB cache) | 2 cores, 2 chips, 1 core/chip | TCP | 27023 | 0.82 | HTML Text PS |
Network Appliance, Inc. | GF960c Failover Cluster/HDS 9980V (32GB cache) | 4 cores, 4 chips, 1 core/chip (2 per node) | TCP | 50139 | 1.04 | HTML Text PS |
ONStor, Inc. | ONStor Bobcat 2220 NAS Gateway / 3PAR InServ S800 Storage Server | 4 cores, 2 chips, 2 cores/chip | TCP | 10120 | 1.35 | HTML Text PS |
ONStor, Inc. | ONStor Bobcat 2240 NAS Gateway / 3PAR InServ S800 Storage Server | 4 cores, 2 chips, 2 cores/chip | TCP | 18280 | 1.18 | HTML Text PS |
ONStor, Inc. | ONStor Bobcat 2260 NAS Gateway (four gateway cluster) / 3PAR InServ S800 Storage Server | 16 cores, 8 chips, 2 cores/chip | TCP | 128236 | 1.30 | HTML Text PS |
ONStor, Inc. | ONStor Bobcat 2260 NAS Gateway / 3PAR InServ S800 Storage Server | 4 cores, 2 chips, 2 cores/chip | TCP | 31784 | 1.53 | HTML Text PS |
ONStor, Inc. | ONStor Bobcat 2260 NAS Gateway / 3PAR InServ S800 Storage Server (RAID-1) | 4 cores, 2 chips, 2 cores/chip | TCP | 30530 | 1.78 | HTML Text PS |
ONStor, Inc. | ONStor SF4420 / 3PAR InServ S400 Storage Server | 4 (see notes) | TCP | 18207 | 0.89 | HTML Text PS |
ONStor, Inc. | ONStor SF4440 / 3PAR InServ S400 Storage Server | 4 (see notes) | TCP | 35624 | 1.72 | HTML Text PS |
ONStor, Inc. | ONStor SF4440-HA (2-filer cluster) / 3PAR InServ S400 Storage Server | 8 (see notes) | TCP | 71334 | 1.69 | HTML Text PS |
Panasas, Inc. | Panasas ActiveScale storage cluster (10 DirectorBlades) | 10 (1 per DirectorBlade) | TCP | 50907 | 1.67 | HTML Text PS |
Panasas, Inc. | Panasas ActiveScale storage cluster (60 DirectorBlades) | 60 (1 per DirectorBlade) | TCP | 305805 | 1.76 | HTML Text PS |
Pillar Data Systems | Axiom ™ 500 | 8 cores, 8 chips, 1 core/chip (4 cores per Slammer) | TCP | 54431 | 1.37 | HTML Text PS |
Procom Technology Inc. | NetFORCE 1800 | 1 | TCP | 13291 | 1.96 | HTML Text PS |
Procom Technology Inc. | NetFORCE 3500 | 1 | UDP | 12048 | 3.42 | HTML Text PS |
Procom Technology Inc. | NetFORCE 3600C ( Failover Cluster ) | 2 (1 per node) | UDP | 20138 | 3.09 | HTML Text PS |
Procom Technology Inc. | NetFORCE 4100 | 1 | TCP | 18146 | 1.85 | HTML Text PS |
Procom Technology Inc. | NetFORCE 4200c (Failover Cluster) | 2(one per node) | TCP | 33175 | 1.94 | HTML Text PS |
Silicon Graphics, Inc. | SGI Infinite Storage NAS 2000 (A350 2P) | 2 cores, 2 chips, 1 core/chip | TCP | 13048 | 2.60 | HTML Text PS |
Silicon Graphics, Inc. | SGI InfiniteStorage NAS 3000 (A350 4P) | 4 cores, 4 chips, 1 core/chip | TCP | 37348 | 1.31 | HTML Text PS |
Silicon Graphics, Inc. | SGI InfiniteStorage NAS 3000 (A350 8P) | 8 cores, 8 chips, 1 core/chip | TCP | 57674 | 1.07 | HTML Text PS |
Silicon Graphics, Inc. | SGI InfiniteStorage NEXIS 2000 SAS | 4 cores, 2 chips, 2 cores/chip | TCP | 33313 | 1.55 | HTML Text PS |
Spinnaker Networks | SpinServer 4100 | 2 | TCP | 34943 | 1.77 | HTML Text PS |
Spinnaker Networks | SpinServer 4100 | 2 | UDP | 36919 | 1.86 | HTML Text PS |
Spinnaker Networks | SpinServer 4100 (3-node Scalable Cluster, HA Failover) | 6 (2 per node) | TCP | 75735 | 1.81 | HTML Text PS |
Spinnaker Networks | SpinServer 4100 (5-node Scalable Cluster) | 10 (2 per node) | TCP | 134385 | 1.90 | HTML Text PS |
Spinnaker Networks, Inc. | SpinServer 3300 | 2 | TCP | 23363 | 1.93 | HTML Text PS |
Spinnaker Networks, Inc. | SpinServer 3300 | 2 | UDP | 31876 | 1.71 | HTML Text PS |
Spinnaker Networks, Inc. | SpinServer 3300 (6-node scalable cluster) | 12 (2 per node) | TCP | 117538 | 1.94 | HTML Text PS |
Spinnaker Networks, Inc. | SpinServer 3300 (6-node scalable cluster) | 12 (2 per node) | UDP | 131930 | 2.01 | HTML Text PS |
Sun Microsystems | Netra 20 | 2 | TCP | 12304 | 1.79 | HTML Text PS |
Sun Microsystems | Netra 20 | 2 | UDP | 12943 | 1.72 | HTML Text PS |
Sun Microsystems | Sun Fire 280R | 2 | TCP | 12304 | 1.79 | HTML Text PS |
Sun Microsystems | Sun Fire 280R | 2 | UDP | 12943 | 1.72 | HTML Text PS |
Sun Microsystems, Inc. | StorEdge 5210 NAS | 1 core, 1 chip, 1 core/chip | TCP | 11721 | 1.46 | HTML Text PS |
Sun Microsystems, Inc. | StorEdge 5310 NAS | 1 core, 1 chip, 1 core/chip | TCP | 17871 | 2.19 | HTML Text PS |
Sun Microsystems, Inc. | StorEdge 5310C NAS Failover Cluster | 2 cores, 2 chips, 1 core/chip (1 core per node) | TCP | 34074 | 1.83 | HTML Text PS |
Sun Microsystems, Inc. | Sun Fire V250 | 2 | TCP | 15161 | 1.74 | HTML Text PS |
Sun Microsystems, Inc. | Sun Fire V250 | 2 | UDP | 17613 | 1.75 | HTML Text PS |
Sun Microsystems, Inc. | Sun StorageTek 5320 NAS | 1 core, 1 chip, 1 core/chip | TCP | 28074 | 2.24 | HTML Text PS |
Sun Microsystems, Inc. | Sun StorageTek 5320C NAS | 2 cores, 2 chips, 1 core/chip (1 core per node) | TCP | 53548 | 2.53 | HTML Text PS |
Traakan, Inc. | RainFiler (1-Node,16x36,TCP) | 1 | TCP | 9051 | 2.88 | HTML Text PS |
Traakan, Inc. | RainFiler (1-Node,32x36,TCP) | 1 | TCP | 11143 | 2.58 | HTML Text PS |
Traakan, Inc. | RainFiler (1-Node,40x36,TCP) | 1 | TCP | 16166 | 2.53 | HTML Text PS |
Traakan, Inc. | RainFiler (Failover,1-Node,4x36,TCP) | 1 | TCP | 1957 | 2.31 | HTML Text PS |
Traakan, Inc. | RainFiler(1-Node,4x36GB,TCP) | 1 | TCP | 2211 | 2.12 | HTML Text PS |
VERITAS Software Corp. | VERITAS ServPoint NAS 1.2 | 2 | TCP | 6064 | 1.97 | HTML Text PS |
VERITAS Software Corp. | VERITAS ServPoint NAS 1.2 | 2 | UDP | 6602 | 1.98 | HTML Text PS |
VERITAS Software Corp. | VERITAS ServPoint NAS 1.2 HA (Failover Cluster) | 4 (2 per node) | TCP | 11626 | 2.35 | HTML Text PS |
VERITAS Software Corp. | VERITAS ServPoint NAS 1.2 HA (Failover Cluster) | 4 (2 per node) | UDP | 11672 | 2.22 | HTML Text PS |
VERITAS Software Corp. | VERITAS ServPoint NAS 1.2.1 | 8 | TCP | 23035 | 2.40 | HTML Text PS |
VERITAS Software Corp. | VERITAS ServPoint NAS 1.2.1 | 8 | UDP | 24787 | 2.37 | HTML Text PS |
Company | System | CPU # | Proto | Result | ORT1 | Disclosure |
---|---|---|---|---|---|---|
Auspex Systems, Inc. | BRAT (RAID0, NetOS 4.2) | 2 | UDP | 18270 | 2.65 | HTML Text PS |
Auspex Systems, Inc. | BRAT (RAID5, NetOS 4.2) | 2 | UDP | 13412 | 3.35 | HTML Text PS |
Auspex Systems, Inc. | NS3010 (RAID0, NetOS 4.2) | 2 | UDP | 20113 | 3.04 | HTML Text PS |
Auspex Systems, Inc. | NS3010 (RAID5, NetOS 4.2) | 2 | TCP | 16063 | 3.62 | HTML Text PS |
Auspex Systems, Inc. | NS3010 (RAID5, NetOS 4.2) | 2 | UDP | 19034 | 3.56 | HTML Text PS |
Compaq Computer Corporation | Compaq AlphaServer ES45 1000 | 4 | UDP | 37788 | 1.45 | HTML Text PS |
Hewlett Packard | HP AlphaServer ES45 1250 | 4 | UDP | 44618 | 1.56 | HTML Text PS |
Hewlett Packard | HP AlphaServer GS1280 Model 16 7/1150 | 16 | UDP | 154654 | 1.15 | HTML Text PS |
Hewlett Packard | HP AlphaServer GS1280 Model 4 7/1150 | 4 | UDP | 57679 | 1.27 | HTML Text PS |
Hewlett Packard | HP AlphaServer GS1280 Model 8 7/1150 | 8 | UDP | 107149 | 1.39 | HTML Text PS |
Hewlett Packard | HP Surestore NAS-105L | 4 | TCP | 15087 | 4.46 | HTML Text PS |
Hewlett Packard | HP Surestore NAS-105L | 4 | UDP | 15477 | 3.29 | HTML Text PS |
Hewlett Packard | HP Surestore NAS-105LC Failover Cluster | 8 (4 processors/node) | TCP | 24678 | 4.05 | HTML Text PS |
Hewlett Packard | HP Surestore NAS-105LC Failover Cluster | 8 (4 processors/node) | UDP | 25116 | 3.76 | HTML Text PS |
Hewlett Packard | HP server rp5470 | 4 | TCP | 20495 | 1.65 | HTML Text PS |
Hewlett Packard | HP server rp5470 | 4 | UDP | 23592 | 1.71 | HTML Text PS |
Hewlett Packard | HP surestore NAS VA 105J | 2 | UDP | 14044 | 2.70 | HTML Text PS |
Hewlett Packard | rp2470 | 2 | TCP | 14462 | 1.45 | HTML Text PS |
Hewlett Packard | rp2470 | 2 | UDP | 17112 | 1.48 | HTML Text PS |
Hewlett Packard | rp7410 | 8 | TCP | 36352 | 2.88 | HTML Text PS |
Hewlett Packard | rp7410 | 8 | UDP | 56983 | 3.07 | HTML Text PS |
Hewlett-Packard | HP Integrity Server rx7620 | 8 | UDP | 71013 | 1.73 | HTML Text PS |
Hewlett-Packard | HP ProLiant DL585 G2 Storage Server | 8 cores, 4 chips, 2 cores/chip | UDP | 40284 | 1.05 | HTML Text PS |
Hewlett-Packard | HP ProLiant DL585 G2 Storage Server | 8 cores, 4 chips, 2 cores/chip | TCP | 40817 | 1.40 | HTML Text PS |
Hewlett-Packard | HP Server rx5670 | 4 | TCP | 27052 | 1.50 | HTML Text PS |
Hewlett-Packard | HP Server rx5670 | 4 | UDP | 37068 | 1.42 | HTML Text PS |
Hewlett-Packard | HP server rp7400 | 4 | TCP | 17274 | 1.82 | HTML Text PS |
Hewlett-Packard | HP server rp7400 | 4 | UDP | 19934 | 2.12 | HTML Text PS |
Hewlett-Packard | HP surestore NAS VA 105A | 2 | UDP | 11334 | 2.94 | HTML Text PS |
Hewlett-Packard | HP surestore NAS VA 105L | 2 | UDP | 13587 | 2.74 | HTML Text PS |
Hewlett-Packard | hp ProLiant DL380 G4 Storage Server SAN Storage Model | 2 cores, 2 chips, 1 core/chip (Hyper-Threading Technology enabled) | UDP | 14844 | 1.42 | HTML Text PS |
Hewlett-Packard | hp ProLiant DL580G2 Storage Server | 4 cores, 4 chips, 1 core/chip | TCP | 11937 | 1.75 | HTML Text PS |
Hewlett-Packard | hp ProLiant DL580G2 Storage Server | 4 cores, 4 chips, 1 core/chip | UDP | 13319 | 1.44 | HTML Text PS |
Hewlett-Packard | hp server rx4610 | 4 | TCP | 18369 | 1.59 | HTML Text PS |
Hewlett-Packard | hp server rx4610 | 4 | UDP | 22284 | 1.63 | HTML Text PS |
IBM Corporation | IBM eServer pSeries 620 Model 6F0 | 4 | UDP | 36427 | 1.70 | HTML Text PS |
IBM Corporation | IBM eServer pSeries 620 Model 6F1 | 4 | UDP | 36427 | 1.70 | HTML Text PS |
IBM Corporation | IBM eServer pSeries 630 Model 6C4 (TCP) | 4 | TCP | 45063 | 1.85 | HTML Text PS |
IBM Corporation | IBM eServer pSeries 630 Model 6C4 (UDP) | 4 | UDP | 44983 | 1.77 | HTML Text PS |
IBM Corporation | IBM eServer pSeries 630 Model 6E4 (TCP) | 4 | TCP | 45063 | 1.85 | HTML Text PS |
IBM Corporation | IBM eServer pSeries 630 Model 6E4 (UDP) | 4 | UDP | 44983 | 1.77 | HTML Text PS |
IBM Corporation | IBM eServer pSeries 650 Model 6M2 (TCP) | 8 | TCP | 71075 | 1.61 | HTML Text PS |
IBM Corporation | IBM eServer pSeries 650 Model 6M2 (UDP) | 8 | UDP | 70894 | 1.58 | HTML Text PS |
IBM Corporation | IBM eServer pSeries 655 (UDP) | 4 | UDP | 58830 | 1.62 | HTML Text PS |
IBM Corporation | IBM eServer pSeries 660 Model 6M1 | 8 | UDP | 53745 | 1.69 | HTML Text PS |
IBM Corporation | IBM eServer pSeries 690 (1.7GHz, TCP) | 16 | TCP | 167007 | 1.08 | HTML Text PS |
IBM Corporation | IBM eServer pSeries 690 Turbo | 16 | UDP | 111687 | 1.39 | HTML Text PS |
Procom Technology Inc. | NetFORCE 3500 | 1 | UDP | 14232 | 2.10 | HTML Text PS |
Procom Technology Inc. | NetFORCE 3600C ( Failover Cluster ) | 2 (1 per node) | UDP | 24754 | 2.29 | HTML Text PS |
Traakan, Inc. | RainFiler (1-Node,32x36,UDP) | 1 | UDP | 14740 | 2.12 | HTML Text PS |
Traakan, Inc. | RainFiler (1-Node,40x36,UDP) | 1 | UDP | 20772 | 2.21 | HTML Text PS |
1 ORT = Overall Response Time
Back to [SFS97_R1 Results]