Hewlett Packard Enterprise ProLiant DL385 Gen11 SPECpower_ssj2008 = 26,228 overall ssj_ops/watt
Test Sponsor: Hewlett Packard Enterprise SPEC License #: 3 Test Method: Single Node
Tested By: Hewlett Packard Enterprise Test Location: Houston, TX, USA Test Date: Oct 19, 2022
Hardware Availability: Dec-2022 Software Availability: Dec-2022 Publication: Nov 10, 2022
System Source: Single Supplier System Designation: Server Power Provisioning: Line-powered
Benchmark Results Summary
Performance Power Performance to Power Ratio
Target Load Actual Load ssj_ops Average Active Power (W)
100% 99.5% 23,277,226 720 32,323
90% 89.5% 20,935,498 674 31,059
80% 79.9% 18,693,451 623 29,984
70% 69.9% 16,346,309 559 29,226
60% 60.0% 14,028,292 468 30,000
50% 50.0% 11,707,105 424 27,614
40% 40.0% 9,354,762 386 24,233
30% 30.0% 7,021,442 348 20,182
20% 20.0% 4,674,256 306 15,287
10% 10.0% 2,339,553 262 8,946
Active Idle 0 125 0
∑ssj_ops / ∑power = 26,228
Graph of results
System Under Test
Set: 'SUT'
Set Identifier: SUT
Set Description: System Under Test
# of Identical Nodes: 1
Comment: SUT
Hardware
Hardware Vendor: Hewlett Packard Enterprise
Model: ProLiant DL385 Gen11
Form Factor: 2U
CPU Name: AMD EPYC 9654 2.40 GHz
CPU Characteristics: 96-Core, 2.40 GHz, 384MB L3 Cache
CPU Frequency (MHz): 2400
CPU(s) Enabled: 192 cores, 2 chips, 96 cores/chip
Hardware Threads: 384 (2 / core)
CPU(s) Orderable: 1,2 chips
Primary Cache: 32 KB I + 32 KB D on chip per core
Secondary Cache: 1 MB I+D on chip per core
Tertiary Cache: 384 MB I+D on chip per chip
Other Cache: None
Memory Amount (GB): 384
# and size of DIMM: 24 x 16384 MB
Memory Details: 16 GB 1Rx8 PC5-4800B-R; all DIMM slots populated on each socket
Power Supply Quantity and Rating (W): 1 x 1000
Power Supply Details: HPE 1000W Flex Slot Titanium Hot Plug Low Halogen Power Supply Kit (P03178-B21)
Disk Drive: 1 x HPE 480GB SATA 6G Read Intensive SFF BC Multi Vendor SSD (P40497-B21)
Disk Controller: Embedded SATA Controller
# and type of Network Interface Cards (NICs) Installed: 1 x HPE 1GbE 4p BASE-T I350-T4 OCP3 Adapter (P08449-B21)
NICs Enabled in Firmware / OS / Connected: 4/4/1
Network Speed (Mbit): 1000
Keyboard: None
Mouse: None
Monitor: None
Optical Drives: No
Other Hardware: None
Software
Power Management: Enabled (see SUT Notes)
Operating System (OS): SUSE Linux Enterprise Server 15 SP4
OS Version: 5.14.21-150400.22-default
Filesystem: xfs
JVM Vendor: Oracle Corporation
JVM Version: Java HotSpot(TM) 64-Bit Server VM 18.9 (build 11.0.15+8-LTS-149, mixed mode)
JVM Command-line Options: -server -Xmn1825m -Xms1995m -Xmx1995m -XX:SurvivorRatio=1 -XX:TargetSurvivorRatio=99 -XX:ParallelGCThreads=2 -XX:AllocatePrefetchDistance=256 -XX:AllocatePrefetchLines=4 -XX:LoopUnrollLimit=45 -XX:InitialTenuringThreshold=12 -XX:MaxTenuringThreshold=15 -XX:InlineSmallCode=3900 -XX:MaxInlineSize=270 -XX:FreqInlineSize=2500 -XX:+UseLargePages -XX:+UseParallelOldGC -XX:UseAVX=1 -XX:BiasedLockingStartupDelay=30000 -XX:-ThreadLocalHandshakes
JVM Affinity: for each even physicalCoreId { numactl -C physicalCoreId, physicalCoreId + 1, physicalCoreId + 192, physicalCoreId + 193 }
JVM Instances: 96
JVM Initial Heap (MB): 1995
JVM Maximum Heap (MB): 1995
JVM Address Bits: 64
Boot Firmware Version: A55 v1.10 (10/14/2022)
Management Firmware Version: 1.10 Oct 09 2022
Workload Version: SSJ 1.2.10
Director Location: Controller
Other Software: HPE ProLiant Agentless Management Service for SUSE LINUX Enterprise Server 15
Boot Firmware Settings
BIOS Platform Configuration (RBSU):
Management Firmware Settings
See SUT Notes
System Under Test Notes
Controller System
Hardware
Hardware Vendor: Hewlett Packard Enterprise
Model: ProLiant DL360 Gen9
CPU Description: 2x Intel Xeon E5-2660 v3
Memory amount (GB): 128
Software
Operating System (OS): Windows Server 2012 R2
JVM Vendor: Oracle Corporation
JVM Version: 1.8.0_241-b07 (build 25.241-b07, mixed mode)
CCS Version: 1.2.6
Measurement Devices
Power Analyzer pwr1
Hardware Vendor: Yokogawa
Model: WT210
Serial Number: 91GB53024
Connectivity: GPIB vi NI GPIB-USB-HS
Input Connection: Default
Metrology Institute: NIST
Accredited by: TRANSCAT
Calibration Label: 5-GU3Q4-100-1
Date of Calibration: 14-Jun-2022
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
PTDaemon Version: 1.9.2-3976349f-20201208
Setup Description: SUT Power Supply 1
Temperature Sensor temp1
Hardware Vendor: Digi International Inc.
Model: Watchport/H
Driver Version: 5.70.105.0
Connectivity: USB
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
Setup Description: 5 mm in front of SUT main intake
Notes
None
Aggregate Electrical and Environmental Data
Target Load Average Active Power (W) Minimum Ambient Temperature (°C)
100% 720 22.1
90% 674 23.6
80% 623 22.3
70% 559 22.5
60% 468 23.9
50% 424 22.6
40% 386 22.9
30% 348 23.9
20% 306 22.4
10% 262 22.5
Active Idle 125 23.6
Line Standard Minimum Temperature (°C) Elevation (m)
208V / 60 Hz / 1 phase / 2 wires 22.1 132
Aggregate Performance Data
Target Load Actual Load ssj_ops
Target Actual
Calibration 1     21,966,539
Calibration 2     23,398,293
Calibration 3     23,390,057
ssj_ops@calibrated=23,394,175
100% 99.5% 23,394,175 23,277,226
90% 89.5% 21,054,758 20,935,498
80% 79.9% 18,715,340 18,693,451
70% 69.9% 16,375,923 16,346,309
60% 60.0% 14,036,505 14,028,292
50% 50.0% 11,697,088 11,707,105
40% 40.0% 9,357,670 9,354,762
30% 30.0% 7,018,253 7,021,442
20% 20.0% 4,678,835 4,674,256
10% 10.0% 2,339,418 2,339,553
Active Idle   0 0
Graph of results