Hewlett-Packard Company ProLiant DL785 G5 (2.30GHz, AMD Opteron 8376 HE) SPECpower_ssj2008 = 872 overall ssj_ops/watt
Test Sponsor: Hewlett-Packard Company SPEC License #: 3 Test Method: Single Node
Tested By: Hewlett-Packard Company Test Location: Cupertino, CA, USA Test Date: Feb 7, 2009
Hardware Availability: Jan-2009 Software Availability: May-2009 Publication: Feb 25, 2009
System Source: Single Supplier System Designation: Server Power Provisioning: Line-powered
Benchmark Results Summary
Performance Power Performance to Power Ratio
Target Load Actual Load ssj_ops Average Active Power (W)
100% 99.2% 1,066,480 796 1,339
90% 89.9% 966,782 765 1,264
80% 80.2% 862,108 731 1,179
70% 70.1% 753,080 699 1,078
60% 59.9% 644,152 662 973
50% 49.9% 536,172 625 859
40% 40.0% 429,488 587 731
30% 29.9% 321,499 542 593
20% 19.9% 214,366 486 441
10% 10.1% 108,242 447 242
Active Idle 0 427 0
∑ssj_ops / ∑power = 872
Graph of results
System Under Test
Set: 'sut'
Set Identifier: sut
Set Description: ProLiant DL785 G5 (2.30GHz, AMD Opteron 8376 HE)
# of Identical Nodes: 1
Comment: None
Hardware
Hardware Vendor: Hewlett-Packard Company
Model: ProLiant DL785 G5 (2.30GHz, AMD Opteron 8376 HE)
Form Factor: --
CPU Name: Quad-Core AMD Opteron(r) Processor 8376 HE
CPU Characteristics: Quad-Core, 2.3GHz, 6MB L3 Cache
CPU Frequency (MHz): 2300
CPU(s) Enabled: 32 cores, 8 chips, 4 cores/chip
Hardware Threads: 32 (1 / core)
CPU(s) Orderable: 4,8 chips
Primary Cache: 64 KB I + 64 KB D on chip per core
Secondary Cache: 512 KB I+D on chip per chip
Tertiary Cache: 6 MB I+D off chip per chip
Other Cache: None
Memory Amount (GB): 32
# and size of DIMM: 16 x 2048 MB
Memory Details: 4GB Reg PC2-5300 2x2GB LP Kit 483401-B21; slots 1 and 2 populated on each board
Power Supply Quantity and Rating (W): 3 x 1200
Power Supply Details: HP P/N 437572-B21
Disk Drive: 1 x 73GB 10K RPM SAS
Disk Controller: Integrated P400i SmartArray controller
# and type of Network Interface Cards (NICs) Installed: 2 x NC373i NIC
NICs Enabled in Firmware / OS / Connected: 2/2/1
Network Speed (Mbit): 1000
Keyboard: KVM
Mouse: KVM
Monitor: None
Optical Drives: Yes
Other Hardware: none
Software
Power Management: HP Dynamic Power Regulator enabled
Operating System (OS): Microsoft Windows Server 2008 x64 Enterprise Edition
OS Version: Build 6001: Service pack 1
Filesystem: NTFS
JVM Vendor: Oracle Corporation
JVM Version: Oracle JRockit(R) 6 P28.0.0 (build P28.0.0-8-109238-1.6.0_05-20090130-1408-windows-x86_64, compiled mode)
JVM Command-line Options: -Xms3600m -Xmx3600m -Xns3100m -XXaggressive -XlargePages -XXthroughputCompaction -XXcallprofiling -Xgc:genpar -XXgcthreads:4 -XXtlasize:min=12k,preferred=1024k
JVM Affinity: Used "start /AFFINITY" "0xF","0xF0","0xF00","0xF000","0xF0000","0xF00000","0xF000000" and "0xF0000000" CPU masks.
JVM Instances: 16
JVM Initial Heap (MB): 3600
JVM Maximum Heap (MB): 3600
JVM Address Bits: 64
Boot Firmware Version: --
Management Firmware Version: --
Workload Version: SSJ 1.1.3
Director Location: Controller
Other Software: None
Boot Firmware Settings
--
Management Firmware Settings
--
System Under Test Notes
Controller System
Hardware
Hardware Vendor: Hewlett-Packard Company
Model: Compaq nc6220
CPU Description: Pentium M
Memory amount (GB): 0.5
Software
Operating System (OS): Ubuntu 8.10 Intrepid Ibex
JVM Vendor: Sun Microsystems
JVM Version: 1.6.0_u10
CCS Version: 1.1.3
Measurement Devices
Power Analyzer pwr1
Hardware Vendor: Yokogawa Electric International Pte. Ltd.
Model: WT210
Serial Number: 91FB02050
Connectivity: RS-232
Input Connection: Default
Calibration Institute: NIST
Accredited by: Instrument Calibration Service
Calibration Label: 67961
Date of Calibration: 02-Dec-2008
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
PTDaemon Version: 1.3.2-62d59d34
Setup Description: --
Temperature Sensor temp1
Hardware Vendor: Digi International Inc.
Model: Watchport/H
Driver Version: OS Supplied
Connectivity: USB
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
Setup Description: --
Notes
The power connection between the power analyzer and the SUT power supplies was a passive power strip and 3 power cords
Aggregate Electrical and Environmental Data
Target Load Average Active Power (W) Minimum Ambient Temperature (°C)
100% 796 20.8
90% 765 20.8
80% 731 20.8
70% 699 20.6
60% 662 20.6
50% 625 20.6
40% 587 20.6
30% 542 20.5
20% 486 20.5
10% 447 20.5
Active Idle 427 20.5
Line Standard Minimum Temperature (°C) Elevation (m)
208V / 60 Hz / 1 phase / 2 wires 20.5 72
Aggregate Performance Data
Target Load Actual Load ssj_ops
Target Actual
Calibration 1     1,105,959
Calibration 2     1,077,880
Calibration 3     1,071,968
ssj_ops@calibrated=1,074,924
100% 99.2% 1,074,924 1,066,480
90% 89.9% 967,432 966,782
80% 80.2% 859,939 862,108
70% 70.1% 752,447 753,080
60% 59.9% 644,954 644,152
50% 49.9% 537,462 536,172
40% 40.0% 429,970 429,488
30% 29.9% 322,477 321,499
20% 19.9% 214,985 214,366
10% 10.1% 107,492 108,242
Active Idle   0 0
Graph of results