Hewlett-Packard Company ProLiant ML110 G5 SPECpower_ssj2008 = 431 overall ssj_ops/watt
Test Sponsor: Intel Corp. SPEC License #: 3184 Test Method: Single Node
Tested By: Principled Technologies, Inc. Test Location: Durham, NC, USA Test Date: Jan 19, 2011
Hardware Availability: Feb-2008 Software Availability: May-2009 Publication: Feb 17, 2011
System Source: Single Supplier System Designation: Server Power Provisioning: Line-powered
Benchmark Results Summary
Target Load Average Active Power (W) Minimum Ambient Temperature (°C)
Calibration 1 135 22.2
Calibration 2 134 22.4
Calibration 3 135 22.4
100% 135 22.4
90% 133 22.4
80% 129 22.4
70% 125 22.6
60% 121 22.3
50% 116 22.5
40% 110 22.3
30% 105 22.4
20% 101 22.3
10% 97.0 22.4
Active Idle 93.7 22.2
Graph of power and temperature
Measurement Devices
Power Analyzer pwr1
Hardware Vendor: Yokogawa Electric International Pte. Ltd.
Model: WT210
Serial Number: 91GB45373
Connectivity: RS-232
Input Connection: Default
Calibration Institute: NIST
Accredited by: Davis Calibration
Calibration Label: 07-1673
Date of Calibration: 28-Jul-2010
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
PTDaemon Version: 1.4.0-7071d9e7
Setup Description: SUT Power Supply
Temperature Sensor temp1
Hardware Vendor: Digi International Inc.
Model: Watchport/H
Driver Version: 5.10.26.0
Connectivity: USB
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
Setup Description: 50 mm in front of SUT main air intake
Notes
Used USB-to-Serial converter, Model Sabrent SBT-USC1M (driver version 2.0.2.1), to connect power analyzer to the controller.

This benchmark result is intended to provide perspective on past power and/or performance using the historical hardware and/or software described on this result page.

The system as described on this result page was formerly generally available. At the time of this publication, it may not be shipping, and/or may not be supported, and/or may fail to meet other tests of General Availability described in the SPEC OSG Policy document, http://www.spec.org/osg/policy.html

This measured result may not be representative of the result that would be measured were this benchmark run with hardware and software available as of the publication date.

Power Details for Device pwr1
Target Load Voltage (V) Current (A) Avg Power Factor Avg Active Power (W) Power Measurement Uncertainty (%)
Avg Range Avg Range
Calibration 1 120 150.0 1.16 2.0 0.968 135 0.4%
Calibration 2 120 150.0 1.15 2.0 0.968 134 0.4%
Calibration 3 120 150.0 1.16 2.0 0.968 135 0.4%
100% 120 150.0 1.16 2.0 0.968 135 0.4%
90% 120 150.0 1.14 2.0 0.966 133 0.4%
80% 120 150.0 1.11 2.0 0.963 129 0.4%
70% 120 150.0 1.09 2.0 0.959 125 0.4%
60% 120 150.0 1.05 2.0 0.955 121 0.4%
50% 120 150.0 1.01 2.0 0.951 116 0.4%
40% 120 150.0 0.966 2.0 0.948 110 0.4%
30% 120 150.0 0.926 2.0 0.947 105 0.5%
20% 120 150.0 0.885 2.0 0.945 101 0.5%
10% 120 150.0 0.857 2.0 0.944 97.0 0.5%
Active Idle 120 150.0 0.826 2.0 0.943 93.7 0.5%
Power details for pwr1