| Hewlett-Packard Company ProLiant DL580 G4 | SPECpower_ssj2008 = 114 overall ssj_ops/watt | ||||
| Test Sponsor: | Intel Corp. | SPEC License #: | 3184 | Test Method: | Single Node |
| Tested By: | Principled Technologies, Inc. | Test Location: | Durham, NC, USA | Test Date: | Jan 20, 2011 |
| Hardware Availability: | Aug-2006 | Software Availability: | May-2009 | Publication: | Feb 17, 2011 |
| System Source: | Single Supplier | System Designation: | Server | Power Provisioning: | Line-powered |
| Target Load | Average Active Power (W) | Minimum Ambient Temperature (°C) |
|---|---|---|
| Calibration 1 | 732 | 20.6 |
| Calibration 2 | 733 | 20.3 |
| Calibration 3 | 733 | 20.3 |
| 100% | 732 | 20.3 |
| 90% | 716 | 20.2 |
| 80% | 704 | 20.6 |
| 70% | 690 | 20.2 |
| 60% | 673 | 20.3 |
| 50% | 656 | 20.4 |
| 40% | 639 | 20.2 |
| 30% | 623 | 20.6 |
| 20% | 607 | 20.2 |
| 10% | 590 | 20.2 |
| Active Idle | 575 | 20.3 |
| Power Analyzer pwr1 | |
|---|---|
| Hardware Vendor: | Yokogawa Electric International Pte. Ltd. |
| Model: | WT210 |
| Serial Number: | 91GB45373 |
| Connectivity: | RS-232 |
| Input Connection: | Default |
| Calibration Institute: | NIST |
| Accredited by: | Davis Calibration |
| Calibration Label: | 07-1673 |
| Date of Calibration: | 28-Jul-2010 |
| PTDaemon Host System: | same as CCS |
| PTDaemon Host OS: | same as CCS |
| PTDaemon Version: | 1.4.0-7071d9e7 |
| Setup Description: | SUT Power Supply |
| Temperature Sensor temp1 | |
|---|---|
| Hardware Vendor: | Digi International Inc. |
| Model: | Watchport/H |
| Driver Version: | 5.10.26.0 |
| Connectivity: | USB |
| PTDaemon Host System: | same as CCS |
| PTDaemon Host OS: | same as CCS |
| Setup Description: | 50 mm in front of SUT main air intake |
This benchmark result is intended to provide perspective on past power and/or performance using the historical hardware and/or software described on this result page.
The system as described on this result page was formerly generally available. At the time of this publication, it may not be shipping, and/or may not be supported, and/or may fail to meet other tests of General Availability described in the SPEC OSG Policy document, http://www.spec.org/osg/policy.html
This measured result may not be representative of the result that would be measured were this benchmark run with hardware and software available as of the publication date.
| Target Load | Voltage (V) | Current (A) | Avg Power Factor | Avg Active Power (W) | Power Measurement Uncertainty (%) | ||
|---|---|---|---|---|---|---|---|
| Avg | Range | Avg | Range | ||||
| Calibration 1 | 210 | 300.0 | 3.53 | 5.0 | 0.986 | 732 | 0.3% |
| Calibration 2 | 210 | 300.0 | 3.53 | 5.0 | 0.986 | 733 | 0.3% |
| Calibration 3 | 210 | 300.0 | 3.53 | 5.0 | 0.987 | 733 | 0.3% |
| 100% | 211 | 300.0 | 3.52 | 5.0 | 0.987 | 732 | 0.3% |
| 90% | 210 | 300.0 | 3.45 | 5.0 | 0.986 | 716 | 0.3% |
| 80% | 210 | 300.0 | 3.40 | 5.0 | 0.985 | 704 | 0.3% |
| 70% | 211 | 300.0 | 3.33 | 5.0 | 0.983 | 690 | 0.4% |
| 60% | 210 | 300.0 | 3.26 | 5.0 | 0.983 | 673 | 0.4% |
| 50% | 211 | 300.0 | 3.17 | 5.0 | 0.981 | 656 | 0.4% |
| 40% | 211 | 300.0 | 3.09 | 5.0 | 0.980 | 639 | 0.4% |
| 30% | 211 | 300.0 | 3.02 | 5.0 | 0.980 | 623 | 0.4% |
| 20% | 211 | 300.0 | 2.94 | 5.0 | 0.980 | 607 | 0.4% |
| 10% | 211 | 300.0 | 2.86 | 5.0 | 0.980 | 590 | 0.4% |
| Active Idle | 211 | 300.0 | 2.78 | 5.0 | 0.981 | 575 | 0.4% |