Hewlett-Packard Company ProLiant DL580 G3 SPECpower_ssj2008 = 61.1 overall ssj_ops/watt
Test Sponsor: Intel Corp. SPEC License #: 3184 Test Method: Single Node
Tested By: Principled Technologies, Inc. Test Location: Durham, NC, USA Test Date: Jan 21, 2011
Hardware Availability: Nov-2005 Software Availability: May-2009 Publication: Feb 17, 2011
System Source: Single Supplier System Designation: Server Power Provisioning: Line-powered
Benchmark Results Summary
Target Load Average Active Power (W) Minimum Ambient Temperature (°C)
Calibration 1 831 20.3
Calibration 2 835 20.5
Calibration 3 834 20.2
100% 833 20.5
90% 818 20.2
80% 803 20.4
70% 787 20.4
60% 766 20.3
50% 740 20.6
40% 705 20.3
30% 646 20.4
20% 587 20.2
10% 551 20.3
Active Idle 520 20.3
Graph of power and temperature
Measurement Devices
Power Analyzer pwr1
Hardware Vendor: Yokogawa Electric International Pte. Ltd.
Model: WT210
Serial Number: 91GB45373
Connectivity: RS-232
Input Connection: Default
Calibration Institute: NIST
Accredited by: Davis Calibration
Calibration Label: 07-1673
Date of Calibration: 28-Jul-2010
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
PTDaemon Version: 1.4.0-7071d9e7
Setup Description: SUT Power Supply
Temperature Sensor temp1
Hardware Vendor: Digi International Inc.
Model: Watchport/H
Driver Version: 5.10.26.0
Connectivity: USB
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
Setup Description: 50 mm in front of SUT main air intake
Notes
Used USB-to-Serial converter, Model Sabrent SBT-USC1M (driver version 2.0.2.1), to connect power analyzer to the controller.

This benchmark result is intended to provide perspective on past power and/or performance using the historical hardware and/or software described on this result page.

The system as described on this result page was formerly generally available. At the time of this publication, it may not be shipping, and/or may not be supported, and/or may fail to meet other tests of General Availability described in the SPEC OSG Policy document, http://www.spec.org/osg/policy.html

This measured result may not be representative of the result that would be measured were this benchmark run with hardware and software available as of the publication date.

Power Details for Device pwr1
Target Load Voltage (V) Current (A) Avg Power Factor Avg Active Power (W) Power Measurement Uncertainty (%)
Avg Range Avg Range
Calibration 1 211 300.0 3.99 5.0 0.988 831 0.3%
Calibration 2 210 300.0 4.01 5.0 0.990 835 0.3%
Calibration 3 211 300.0 4.00 5.0 0.990 834 0.3%
100% 210 300.0 4.00 5.0 0.990 833 0.3%
90% 211 300.0 3.93 5.0 0.988 818 0.3%
80% 210 300.0 3.87 5.0 0.987 803 0.3%
70% 211 300.0 3.79 5.0 0.986 787 0.3%
60% 211 300.0 3.69 5.0 0.984 766 0.3%
50% 211 300.0 3.58 5.0 0.982 740 0.3%
40% 211 300.0 3.42 5.0 0.979 705 0.4%
30% 211 300.0 3.14 5.0 0.976 646 0.4%
20% 211 300.0 2.86 5.0 0.972 587 0.4%
10% 210 300.0 2.70 5.0 0.973 551 0.4%
Active Idle 211 300.0 2.54 5.0 0.974 520 0.4%
Power details for pwr1