SPECjAppServer®2004 Result Copyright © 2004 Standard Performance Evaluation Corporation |
Oracle WebLogic Server Standard Edition Release 10.3.1 on Sun SPARC Enterprise T5440 |
|
Submitter: Sun Microsystems Inc. |
SPEC license # 6 | Test date: Jun-2009 |
SUT Configuration | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||
|
Benchmark Settings | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Detailed Results | ||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||
|
||||||||||||||||||||||||||
|
||||||||||||||||||||||||||
|
Oracle WebLogic Server Standard Edition Release 10.3.1 | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Java HotSpot(TM) 32-Bit Server VM on Solaris, version 1.6.0_14 Performance Release | ||||||
---|---|---|---|---|---|---|
|
Java HotSpot(TM) 64-Bit Server VM on Solaris, version 1.6.0_11 | ||||||
---|---|---|---|---|---|---|
|
Java HotSpot(TM) 32-Bit Server VM on Solaris, version 1.6.0_06 Performance Release | ||||||
---|---|---|---|---|---|---|
|
Oracle JDBC Driver 11.1.0.7(Thin) | ||||||
---|---|---|---|---|---|---|
|
Oracle Database 11g Enterprise Edition Release 11.1.0.7 | ||||||
---|---|---|---|---|---|---|
|
J2EE Application Server | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||
|
Emulator SW Config | ||||||||
---|---|---|---|---|---|---|---|---|
|
||||||||
|
Database SW Config | ||||||
---|---|---|---|---|---|---|
|
||||||
|
Driver SW Config - Primary & Satellites | ||||||
---|---|---|---|---|---|---|
|
||||||
|
J2EE AppServer HW (SUT hardware) | ||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||||||
|
Database Server HW (SUT hardware) | ||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||||||
|
Primay Load Driver and Satellites (non-SUT hardware) | ||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||||||
|
Emulator (non-SUT hardware) | ||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||||||
|
DNS Server (SUT hardware) | ||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||||||
|
Benchmark Modifications |
---|
Schema Modifications:
Tablespace sizes were increased to support the Injection rate. Scripts to create the DB are included in the FDA. Table and index initrans were modified. The following tables were horizontally partitioned: C_customerinventory, C_customer, M_workorder, M_inventory, O_orders, O_orderline, S_component, and S_purchase_orderline. The M_parts and M_bom tables were hash clustered. Automatic segment space management was used for all tablespaces. System managed undo was used. Table locks were disabled during the run using disable_locks.sh script. |
Load Program Modifications:
The load program was not modified |
Benchmark Configuration Information |
---|
Isolation Requirement Info:
The following Beans were deployed in READ_COMMITTED mode as per the benchmark requirement: Mfg - AssemblyEnt, BomEnt, ComponentEnt, LargeOrderEnt, PartEnt Orders - ItemEnt Supplier - SupplierCompEnt, SupplierEnt All other beans were deployed using pessimistic locking mode such that all selects including finders are issued with a FOR UPDATE clause in select statement: Corp - CustomerEnt, CustomerInventoryEnt Mfg - InventoryEnt, WorkOrderEnt Orders - OrderEnt, OrderLineEnt Supplier - POEnt, POLineEnt, SComponentEnt Util - SequenceEnt The ItemEnt bean was cached for 20 minute intervals by setting: concurrency-strategy to ReadOnly and read-timeout-seconds to 1200 in bea-orders.xml deployment descriptor. |
Durability Requirement Info:
To ensure database durability, RAID 1 (mirror disks) was used for the database files and logs maintained on the StorageTek ST2540 & 2501 Storage Arrays. The application server used a pair of internal SSD disks using a ZFS mirror to provide durability for the server logs and JMS persistence filestore. |
Storage Requirement Info:
A 75 minute run at an injection rate of 4600 increased storage by 4549 MB This extrapolates to 85 GB storage for a 24 hour run. The database was configured with 17TB of storage. Four sets of Sun StorageTek 2540/2501 daisy-chained pairs were configured as 8 RAID 1 logical drives for the database files. Two Sun StorageTek 2540 FC Arrays (12 x 146GB) where configured as 2 RAID 1 logical drives to store the database redo logs. |
Argument Passing Semantics:
Oracle WebLogic Server 10.3.1 uses pass-by-value as required by the EJB Specification |
Bill of Materials |
---|
Supplier Description Product No. Qty -------- ------------------------------------------ ------------------ --- Sun SPARC Enterprise T5440, 1.6GHz, 4x 8-core SEVPJSF3Z 1 Sun 8GB Memory Expansion Kit SESX2C4Z 16 Sun 10 GbE XAUI card - Fiber SESX7XA1Z 2 Sun Transceiver for XAUI - 10GbE SR XFP SESX7XT1Z 2 Sun PCI-E Quad port GigE X4447A-Z 1 Sun 32GB SATA SSD SESX3Y11Z 2 Sun Solaris 10 5/09 Media Kit SOLZ9-10KC9A7M 1 Sun In-Warranty Upgrade: 3YGOLD, 24x7 IWU-T5440-4P-24-3G 1 Sun SPARC Enterprise T5440, 1.4GHz, 4x 8-core SEVPHSF1Z 1 Sun 8GB Memory Expansion Kit SESX2C1Z 16 Sun PCI-E Quad port GigE X4447A-Z 1 Sun 4 Gb PCI-E Dual Port FC/AL card SG-XPCIE2FC-EM4 3 Sun In-Warranty Upgrade: 3YGOLD, 24x7 IWU-T5440-4P-24-3G 1 Sun SPARC Enterprise M3000, 2.52GHz, 1P SEWPACA1Z 1 Sun SPARC Enterprise M3000, 4x4GB DIMM SEWX2C1Z 1 Sun PCI-E Dual 10GigE Fiber XFP Adapter X1027A-Z 1 Sun XFP SR Transceiver X5558A 1 Sun Solaris 10 10/08 SESY9SD1Z 1 Sun In-Warranty Upgrade: 3YGOLD, 24x7 IWU-M3K1-24-3G 1 Sun Sun StorageTek 2540, 12 x 146GB, 2 RAID XTA2540R01D2E1752 6 Sun Sun StorageTek 2501, 12 x 146GB, EXP Array XTA2501R01D2E1752 4 Sun SunSpectum Upgrade: 3Y GOLD, 24x7 IWU-ST2540NW-24-3G 6 Sun SunSpectum Upgrade: 3Y GOLD, 24x7 IWU-ST2501NW-24-3G 4 Sun 17" Entry Color Monitor X7204A 1 Sun XVR-300 Graphics Accelerator X3000A 1 Sun USB Keyboard & Mouse 320-1366 1 Oracle Oracle Database 11g Release 1 Enterprise Edition, Per Processor 24** (v11.1.0.7) Oracle Partitioning, Per Processor, Unlimited users for 3 years 24** Oracle Oracle Premium Support for 3 years 2 Oracle Oracle WebLogic Server Standard Edition, 10.3.1 24** Oracle Oracle Premium Support for 3 years 1 (** 24 = 0.75 * 32). Explanation: For the purposes of counting the number of processors which require licensing, a multicore chip with "n" cores shall be determined by multiplying "n" cores by a factor of .75). |
Other Benchmark Information |
---|
This submission used the xerces implementation 2.8.1 provided with Oracle WebLogic 10.3.1. Requests were sent to the Appservers using DNS round robin. |
General Notes |
---|
The only errors in the driver log files were those that are normally generated by this benchmark. On the database, incremental checkpointing ensured that no buffer will remain dirty (in the cache) for more than the allowed time. 10 GbE Switch Details: 2x Foundry EdgeIron 8-port 10GbE Switch - Product No. EIF8X10G 16x 10GbE XFP Transceivers - Product No. 10G-XFP-SR 1x Asante FriendlyNet GX5_1600 Gbit switch used between primary driver and database. |
For questions about this result, please contact the submitter: Sun Microsystems Inc. For other inquiries, please contact webmaster@spec.org
Copyright © 2004 Standard Performance Evaluation Corporation
First published at SPEC.org on 21-Jul-2009