SPECjAppServer®2004 Result Copyright © 2004 Standard Performance Evaluation Corporation |
BEA WebLogic Server 9.2 on Inspur NF380D System |
|
Submitter: Inspur (Beijing) Electronic Information Industry Co.,Ltd |
SPEC license # 3358 | Test date: Nov-2006 |
SUT Configuration | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||
|
Benchmark Settings | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Detailed Results | ||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||
|
||||||||||||||||||||||||||
|
||||||||||||||||||||||||||
|
BEA WebLogic Server 9.2, Advantage Edition | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
BEA JRockit(R) 5.0 JDK (R27.1.0-63) (64-bit) | ||||||
---|---|---|---|---|---|---|
|
BEA JRockit(R) 5.0 JDK (R26.4.0-63) (64-bit) | ||||||
---|---|---|---|---|---|---|
|
IBM DB2 Universal JDBC Drivers | ||||||
---|---|---|---|---|---|---|
|
IBM DB2 Universal Database v8.2.6 (64-bit) | ||||||
---|---|---|---|---|---|---|
|
J2EE Configuration | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||
|
Emulator SW Config | ||||||||
---|---|---|---|---|---|---|---|---|
|
||||||||
|
Database SW Config | ||||||
---|---|---|---|---|---|---|
|
||||||
|
Driver SW Config | ||||||
---|---|---|---|---|---|---|
|
||||||
|
J2EE AppServer HW (SUT hardware) | ||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||||||
|
Database Server HW (SUT hardware) | ||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||||||
|
Load Driver HW (non-SUT hardware) | ||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||||||
|
Emulator Server HW (non-SUT hardware) | ||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||||||
|
Benchmark Modifications |
---|
Schema Modifications:
Tablespace sizes were increased to support the Injection rate. Scripts to create the DB are included in the FDA. |
Load Program Modifications:
The load program was not modified. |
Benchmark Configuration Information |
---|
Isolation Requirement Info:
The following beans: PartEnt, ComponentEnt, AssemblyEnt, BomEnt and LargeOrderEnt in the Manufacturing Domain, ItemEnt in the Orders Domain, and SupplierCompEnt and SupplierEnt in the Supplier Domain were accessed using READ_COMMITTED which is Cursor Stability (CS) for DB2. The remaining beans were accessed using translates to DB2 isolation level of Read Stability (RS) The ItemEnt bean was cached for 15 minute intervals by setting concurrency-strategy to ReadOnly and read-timeout-seconds to 900 in bea-orders.xml deployment descriptor. = |
Durability Requirement Info:
To ensure database durability, RAID 1 (mirror disks) was used for the database logs on the Inspur CX300 array. Each application server has a pair of mirrored disks (using onboard controller) to provide durability for all the server logs and filestore for JMS persistence. |
Storage Requirement Info:
An 75 minute run at an injection rate of 890 increased storage by 723 MB This extrapolates to 14 GB of storage for a 24 hour run. The database is configured with 60 GB of storage. One of the Inspur CX300 disk arrarys was configured as a single RAID 1 logical drive for database log files (including 10 hard drives). The other one was configured as a single RAID 0 logical drive for database data files (including 15 hard drives). |
Argument Passing Semantics:
BEA WebLogic 9.2 uses pass-by-value as required by the EJB Specification. |
Bill of Materials |
---|
Supplier Description Product No. Qty -------- ---------------------------------------- ------------------ --- Inspur CPU_I_5160-XD3.0_F1333_4M V015W010K0L0B00D 4 Inspur CPU heat sink V1934090A0H05009 4 Inspur 8GB memory using 1GB DIMMS V025S07330L0F042 16 Inspur 73GB 10K Hot Plug SAS Drive V0377040G0U03003 6 Inspur RAID_controller_128M_U320_PCI V061M1109120000M 2 Inspur Motherboard_5000P_ESB2_dual_Gbit_NIC V0433040S0L0100A 2 Inspur Power_650W V072R080P0B0700B 2 Inspur CD-ROM_52X V12300B04280500C 2 Inspur Floppy_drive V1250MILS3010000 2 Inspur NF380D_chassis V08950209000000F 2 Inspur Mouse V120B06LS0104000 2 Inspur Keyboard C0A0R0105020H00A 2 Inspur 15" CRT Monitor V110AGJLS0104150 2 Inspur CPU_I_XM3.4_F800_2X1M_16M V014Q010F0P0B00A 4 Inspur CPU heat sink V093J010Z0N00000 4 Inspur 16GB memory using 1GB DIMMS V025M070V0L0C042 16 Inspur 73GB 10K Hot Plug Ultra320 SCSI Drive V034M050G0303002 1 Inspur PCI-X 2 Port 1000 BaseT Gigabit Adapter V052110141711000 1 Inspur PCI-X 2Gb Fibre Channel HBA V0B1304040300000 2 Inspur Power V093Q01100P09000 2 Inspur Chassis_motherboard_dual-port-NIC_CD-ROM V096J011K0000000 1 Inspur USB Floopy Drive V123AMIHE3003004 1 Inspur Mouse V120C06HE0103000 1 Inspur Keyboard C0A0S0105030H008 1 Inspur 15" CRT Monitor V110AGJLS0104150 1 Inspur CX300 disk array V246F0L32130F031 2 Inspur 146GB 10K RPM FC hard drive V03C0070Q0N03000 25 BEA BEA WebLogic Server 9.2 License, Advantage Edition 4 BEA 3-year 24x7x4 Support for WebLogic Server 4 IBM DB2 UDB ENTERPRISE SERVER EDITION PROCESSOR D518GLL 8 LIC+SW MAINT 12 MO IBM DB2 UDB ENTERPRISE SERVER EDITION PROCESSOR E00BILL 16 SW MAINT RNWL 1 ANNIV |
Other Benchmark Information |
---|
The submission used round-robin DNS for load-balance of all network requests. The DNS server was hosted on the database server. This submission used the xerces implementation 2.6.2 provided with WebLogic 9.2 |
General Notes |
---|
The only errors in the driver log files were those that are normally generated by this benchmark. DB2 uses "Soft" checkpoint to ensure that no updates remain unflushed for longer than the allowed time. When DB2 UDB Server changes a database table with an update, insert, or delete operation, the change is initially made in memory, not on disk. When there is not enough space in the memory buffer to read in or write additional data pages, DB2 UDB Server will make space by flushing some modified pages to disk. Modified pages are also written to disk as part of the "Soft" checkpoint to ensure that no updates remain unflushed for longer than the allowed time. Before a change is made to the database, it is first recorded in the transaction log. This ensures that the database can be recovered completely in the event of a failure. Using the transaction log, transactions that started but did not complete prior to a failure can be undone, and transactions recorded as complete in the transaction log but not yet written to disk can be redone. DB2 UDB uses a write-ahead-logging protocol to guarantee recovery. This protocol uses "Soft" checkpoint to write least-recently-used database to disk independent of transaction commit. However, enough log information to redo/undo the change to a database pages is committed to disk before the database page itself is written. This protocol therefore renders checkpoint unnecessary for DB2 UDB. |
For questions about this result, please contact the submitter: Inspur (Beijing) Electronic Information Industry Co.,Ltd For other inquiries, please contact webmaster@spec.org
Copyright © 2004 Standard Performance Evaluation Corporation
First published at SPEC.org on 22-Nov-2006